Connecting; Technical Specifications - Siemens SIMATIC RF600 System Manual

Sensors
Hide thumbs Also See for SIMATIC RF600:
Table of Contents

Advertisement

10.1.5

Connecting

● There are three different (country-specific) mains cables for the EU, UK and US.
● The wide-range power supply unit has total insulation (Safety Class 2), IP65
● It can be mounted using four fixing holes.
10.1.6

Technical specifications

Table 10- 1
Insulation stability (prim./sec.) U
Insulation resistance R
Leakage current I
Safety class (SELV)
Mains buffering t
Ambient temperature
Surface temperature
Storage temperature
Self-heating on full-load
Interference immunity
ESD
HF fields
Burst
Surge
HF injection
Mains quality test
Cooler
Dimensions L x W x H
Weight
Housing / casting
Power supply class
Degree of protection
SIMATIC RF600
System Manual, 10/2009, J31069-D0171-U001-A8-7618
The appropriate mains cable must be connected to the primary input of the power supply.
NOTICE
It is only permissible to insert or remove the mains cable when the power supply is de-
energized.
General technical specifications
ins
leak
h
10.1 Wide-range power supply unit for SIMATIC RF systems
ins p/s
U
= 230 V
, f = 50 Hz
in
AC
Designed for installation in devices of Safety Class 2
U
= 230 V
in
AC
Module top, center
EN 61000-4-2,
4-3 up to 4-6, 4-11
according to CSA
IP 65
Accessories
3.3 kV
AC
>1 GΩ
< 200 µA
≥ 50 ms
-25 °C to +55 °C
Max. 96 °C
-40 °C to +85 °C
max. 45 K
Air discharge: 15 kV
10 V/m
symmetrical: 2
Symmetrical: 1
10 V
rms
Free convection
175 mm x 85 mm x 35 mm
720 g
UL 94-V0
Level 3
309