Transponder/tags
7.2 SIMATIC RF630L Smartlabel
Reading the memory bit
The EPC ID is automatically read during the sensing cycle of the stationary or mobile reader.
(see "SIMATIC RF660R Parameterization Manual", Section "EPC Class 1 GEN 2 protocol
settings" or "SIMATIC RF610M Operating Instructions").
In addition, the TID, the EPC ID, the protocol command bits, the CRC-16 bits, the access
password and the kill password can be read using the "tagDataRead" XML command. (see
"SIMATIC RF660R Function Manual", Section "Smart reader tag data reading" and Section
"FCC channel ID settings").
Reserved memory bank: programming or modifying memory areas
The memory areas of the reserved memory bank can be programmed using the SIMATIC
RF660R reader:
● Using the "tagDataWrite" XML command (see "SIMATIC RF660R Function Manual",
Alternatively, the memory areas of the reserved memory bank can be modified using the
mobile RF610M reader:
● Using the "Write" function in the data editor (see "SIMATIC RF610M Operating
EPC memory bank: programming or modifying EPC ID
The memory area "Protocol Control Bit" is defined by the manufacturer and should not be
changed by the user.
The EPC ID can be programmed using the SIMATIC RF660R reader:
● Using the "tagProgramID" XML command (see "SIMATIC RF660R Function Manual",
Alternatively, the EPC ID can be modified using the mobile RF610M reader:
● Using the "Write ID" function (see "SIMATIC RF610M" Operating Instructions, Section
180
Section "Smart reader tag data writing")
Instructions", Section "Write tag")
Section "Smart reader tag ID programming")
"Write ID"
System Manual, 10/2009, J31069-D0171-U001-A8-7618