System diagnostics
9.2 Error messages and flash codes for RF620R/RF630R
Error code
*)
304
Flashing of
ERR LED
(B#16#..)
1C
28x
1D
1E
30x
1F
31
You will find the meaning of the error numbers in the EPC Global Class 1 Gen 2 document, Annex
I.
Antenna is already switched off
Antenna is already switched on
Mode in SET-ANT command not recognized.
More MDSes are in the transmission window than the SLG is capable
of processing simultaneously.
Only 1 MDS can be processed at a time with FB 45.
With FB 45 and FC 55: there is more than one tag with the same
EPC ID in the antenna field of the reader.
With FC 55: Increase the value in multitag or decrease the number
of MDSes in the field.
With FC 55: A read or write command has been sent on a
transponder (UID) and there are one or more transponders in the
antenna field, for which the contents of the addresses FF00 – FF03
of the EPC ID do not agree (unambiguity when transponder is
accessed via 8-byte long UID).
Power supply of the MDS in the limit range:
Due to short-term power shortage, an MDS loses its
communications status (session), upon which the identical EPC-ID
is sent a second time as soon as the power threshold is exceeded
again.
Increase the reader's radiated power and/or reduce the distance
between antenna and MDS until this effect no longer occurs.
Wrong number of characters in the command message frame.
Running command canceled by RESET (init_run or cancel) or bus
connector removed
Communication with the tag was terminated by init_run.
This error can only be reported on init_run or cancel