Integration into networks
8.1 Integration in IT networks
Parameter
Channels
ResetofLeds
HeartBeatInterval
field_ON_control
Note
For the newly supported readers, the antenna performance must be set in the properties
table. The value under the antenna tab is not relevant.
In general, in the overview of all readers many properties are shown that are only relevant
for the RF660R and RF610M readers. Properties of the newly supported readers that cannot
be set are ignored.
288
Value range
Default
Hexadecimal
00
value:
(all
00 ... 0F
channels
on)
Boolean value:
true
true or false
1000 ... 20000
2000
Hexadecimal value 02
Description
Defines the active channel
Bit 0=865.7 MHz
Bit 1=866.3 MHz
Bit 2=866.9 MHz
Bit 3=867.5 MHz
See MOBY manuals, parameter "field_ON_time"
Activates restart of the ERR-LED,
see MOBY manuals, parameter "option_1"
Time in milliseconds in which the heartbeat is sent to
the reader.
Expert settings for air interface,
see MOBY manuals, parameter "field_ON_control"
System Manual, 10/2009, J31069-D0171-U001-A8-7618