3. Parameterize the following values depending on the used reader:
4. in the configuration software of the RF660R reader:
5. You must subsequently have your desired system requirements measured and verified
SIMATIC RF600
System Manual, 10/2009, J31069-D0171-U001-A8-7618
– Parameterize the RF660R via configuration software
Antenna gain: 8.5 dBi
Cable loss: 4 dB (due to adaptation and damping losses of the connectors)
– Parameterize the RF660R via the XML command "antennaConfig"
In the XML command "antenneConfig", the following must be set for the antenna port
that is used:
(antenna number="1 ... 4"), antenna gain (gain="8.5") and cable loss
(cableLoss="4.0").
Cable loss: 4 dB (due to adaptation and damping losses of the connectors)
– Parameterizing RF630R via SIMATIC commands
Since according to ETSI EN 302 208 V1.2.1 the maximum permissible radiated power
is 2 W ERP, none of the transmitting power settings available to the user
(distance_limiting) can lead to the required maximum permissible radiated power
value being exceeded. The exact radiated power of the reader, together with the
antenna cables and antenna used, are the result of the value used in distance_limiting
0-F and the calculation given in Chapter "Radiated power setting with RF630R".
according to EN 302 308 in an absorber chamber.
You may only use your SIMATIC RF600 system with the new third-party components
when this has been carried out.
6.2 Guidelines for selecting RFID UHF antennas
Antennas