Technical Specifications; Mechanical Data; Electrical Data - Siemens SIMATIC RF600 System Manual

Sensors
Hide thumbs Also See for SIMATIC RF600:
Table of Contents

Advertisement

Transponder/tags
7.4 SIMATIC RF630T
7.4.6

Technical specifications

7.4.6.1

Mechanical data

Property
Dimensions (D x H)
Design
Weight
Installation
7.4.6.2

Electrical data

Property
Air interface
Frequency range
Necessary transmit power
Reading range
Mounting on metal
2)
Writing range
Mounting on metal
2)
Polarization type
Minimum distance to transmit
antenna
Energy source
Multi-tag capability
Reduction of range to about 70% at the band limits 902 MHz or 928 MHz; detection is
1)
guaranteed at 915 MHz due to frequency hopping procedure.
Mounting on a flat surface with a diameter of at least 150 mm and at room temperature.
2)
When the minimum distances are not reached, there is a reduction in the maximum read
3)
and write distances of the transponder.
222
Description
21 mm x 21 mm (without thread), tolerance 1 mm
spanner size 19 mm
Plastic enclosure: PA 6.6 GF, silicone-free
Thread: Stainless steel
approx. 22 g
directly on metal without spacing
Europe
According to ISO 18 000-6 C
865 ... 868 MHz
2 W (ERP)
at least 1.2 m, typically 1.5 m
at least 0.8 m
typically 1.2 m
Linear
Approx. 0.15 m
Energy via electro-magnetic field via
antenna, no battery required
Yes, minimum distance between data
carriers ≥ 50 mm
3)
Description
USA / Canada
According to ISO 18 000-6 C
902 MHz ... 928 MHz
4 W (EIRP)
at least 1.2 m, typically 1.5 m
at least 0.8 m
typically 1.2 m
Linear
Approx. 0.15 m
Energy via electro-magnetic field via
antenna, no battery required
Yes, minimum distance between data
carriers ≥ 50 mm
3)
System Manual, 10/2009, J31069-D0171-U001-A8-7618
1)
SIMATIC RF600

Advertisement

Table of Contents
loading