RF600 system planning
4.2 Possible system configurations
4.2.5
Scenario for outgoing goods
This example scenario shows the outgoing goods area of a warehouse with two loading
gates. Pallets are dispatched through the outgoing goods portals - each pallet is marked with
a tag. These tags also contain user data that provide information about the sender and
receiver of the goods. The data read by the readers are checked to ensure that the pallets
are waiting at the correct outgoing goods portal. Depending on the read results of the reader,
the outgoing portal opens, or it remains closed.
Figure 4-2
38
Outgoing goods
System Manual, 10/2009, J31069-D0171-U001-A8-7618