Readers
5.1 RF660R reader
5.1.1.4
Pin assignment of the serial interfaces
RS 232 connector
Industrial Ethernet
NOTICE
We recommend that only original Siemens Ethernet connectors are used (10 m cable:
Order No. 6GT2891-0HN10; 20 m cable: Order No. 6GT2891-0HN20) for connecting to the
Ethernet socket of the reader. If plug-in connectors from other manufacturers are used, it
may be difficult or even impossible to remove the plug from the reader
84
Pin
Pin assignment
1
RS232_TX
2
N.C.
3
N.C.
4
RS232_RX
5
GND
Pin
Pin assignment
1
Transmit Data (+)
2
Transmit Data (-)
3
Receive Data (+)
4
Terminated
5
Terminated
6
Receive Data (-)
7
Terminated
8
Terminated