Appendix
A.2 National regulations
A.2

National regulations

A.2.1

Exceptions for certain regions in France

The following table defines the permitted frequency bands for the ETSI profile which must be
utilized for special regions in France. The
for transmitting in the EPC Class 1 Gen 2 multi-channel dense interrogator environment. The
EPC Class 1 Gen 2 single-channel regulatory environment can use all frequency bands.
Channel ID
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
Due to a European Commission decision as of 16th May 2007 granting France the
derogation to further limit the emission powers for the use of the frequency band 865.6-867.6
MHz for the radio frequency identification devices (RFID) operating within certain zones on
the territory of France, the operation of the RF600 system is limited to operate within the
power levels indicated above, when it is inside the following regions:
318
italic
entries show the permitted frequency bands
Frequency (MHz)
865.1
865.3
865.5
865.7
865.9
866.1
866.3
866.5
866.7
866.9
867.1
867.3
867.5
867.7
867.9
System Manual, 10/2009, J31069-D0171-U001-A8-7618
Maximum transmit power (W)
0.1
0.1
0.1
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
SIMATIC RF600