Readers
5.1 RF660R reader
5.1.4.2

Technical data according to EPC and ISO

Frequencies
European frequency band
North American frequency band
Frequency band for China
Frequency accuracy
Channel spacing
Modulation methods
Effective radiant power
Range
Reading distance
Antennas mounted on opposing sides
(portal configuration)
Antennas mounted on the same side
96
865 to 868 MHz (10 subchannels LBT at 2 W ERP, 12
subchannels at 0.5 W ERP, 15 subchannels LBT at 0.1 W
ERP)
902 ... 928 MHz (50 channels, frequency hopping)
920.125 to 924.875 MHz (16 subchannels at 2 W ERP, 20
subchannels at 0.1 W ERP)
max.± 10 ppm
EU: 200 kHz
US: 500 kHz
China: 250 kHz
ASK: DSB modulation & PR-ASK modulation
Encoding, Manchester or Pulse Interval (PIE)
Europe / China
0.1 to 2 W ERP
Europe / China
max. 10 m (recommended
maximum value for
configuration)
max. 10 m (recommended
maximum value for
configuration)
System Manual, 10/2009, J31069-D0171-U001-A8-7618
USA
0.4 to 4 W EIRP =
0.24 to 2.4 W ERP
USA
max. 10 m (recommended
maximum value for
configuration)
max. 10 m (recommended
maximum value for
configuration)