Error code
SIMATIC RF600
System Manual, 10/2009, J31069-D0171-U001-A8-7618
Flashing of
ERR LED
(B#16#..)
05
5x
06
6x
07
7x
09
0B
11x
0C
12x
0D
13x
0E
14x
0F
1x
9.2 Error messages and flash codes for RF620R/RF630R
Unknown command
•
Incorrect parameter
•
Function not allowed
•
Mode in SET-ANT command unknown
•
FB 45/FC 55 is sending an uninterpretable command to the MOBY-
ASM.
Command_DB contains invalid command parameters.
•
The command_DB was overwritten by the user
•
The MDS reported an address error.
•
Field disturbance on reader
The reader is receiving interference pulses from the environment.
The distance between two readers is too small and does not
•
correspond to the configuration guidelines
The connecting cable to the reader is defective or too long or does
•
not comply with the specification
No free ETSI transmit channel
Wrong communications standard selected in the init_run command
(e.g. FCC in ETSI reader)
Tag memory cannot be read correctly or cannot be written.
Tag reports an error:
Other error (00000000B) *
•
Insufficient power (00001011B): Tag is in the limit range *
•
Non-specific error (00001111B) *
•
The tag memory cannot be write-accessed.
Tag memory is defective
•
Memory is write-protected (Memory Locked: 000000100B)
•
(The tag memory is PERMA-locked and cannot be overwritten or
the reader password has to be reset)
Error in specified address (address error)
The specified address does not exist on the tag
•
The command must be checked and corrected.
•
This is not the correct tag type.
•
Access attempted to non-existent or non-accessible memory areas
•
( Memoryoverrun: 00000011B)
Password error
Incorrect tag password (the reader password must be set again so
•
that is agrees with the password).
Start-up message from ASM. The ASM was off and has not yet
received an init_run command
Execute an init_run
•
The same physical ASM channel is used in two (or more) UDT 10
•
structures. Check the ASM_address and ASM_channel in
10 structures.
System diagnostics
Description
all
UDT
301