Error code
SIMATIC RF600
System Manual, 10/2009, J31069-D0171-U001-A8-7618
Flashing of
ERR LED
(B#16#..)
05
5x
06
6x
07
7x
09
0B
11x
0C
12x
0D
13x
0E
14x
0F
1x
9.2 Error messages and flash codes for RF620R/RF630R
Unknown command
Incorrect parameter
Function not allowed
Mode in SET-ANT command unknown
FB 45/FC 55 is sending an uninterpretable command to the MOBY-
ASM.
Command_DB contains invalid command parameters.
The command_DB was overwritten by the user
The MDS reported an address error.
Field disturbance on reader
The reader is receiving interference pulses from the environment.
The distance between two readers is too small and does not
correspond to the configuration guidelines
The connecting cable to the reader is defective or too long or does
not comply with the specification
No free ETSI transmit channel
Wrong communications standard selected in the init_run command
(e.g. FCC in ETSI reader)
Tag memory cannot be read correctly or cannot be written.
Tag reports an error:
Other error (00000000B) *
Insufficient power (00001011B): Tag is in the limit range *
Non-specific error (00001111B) *
The tag memory cannot be write-accessed.
Tag memory is defective
Memory is write-protected (Memory Locked: 000000100B)
(The tag memory is PERMA-locked and cannot be overwritten or
the reader password has to be reset)
Error in specified address (address error)
The specified address does not exist on the tag
The command must be checked and corrected.
This is not the correct tag type.
Access attempted to non-existent or non-accessible memory areas
( Memoryoverrun: 00000011B)
Password error
Incorrect tag password (the reader password must be set again so
that is agrees with the password).
Start-up message from ASM. The ASM was off and has not yet
received an init_run command
Execute an init_run
The same physical ASM channel is used in two (or more) UDT 10
structures. Check the ASM_address and ASM_channel in
10 structures.