7.7.3.6

Directional radiation pattern of the transponder on metallic surfaces

It is recommendable to align the transponder parallel to the transmitting antenna. If,
however, the transponder including the metallic carrier plate is tilted, the reading range will
be reduced.
Rotation about the polarization axis or orthogonal to the polarization axis
Figure 7-43
Note
Please note that the directional effect is dependent on the size of the metal surface. The
larger the metal surface, the larger the directional effect.
SIMATIC RF600
System Manual, 10/2009, J31069-D0171-U001-A8-7618
100
90
80
70
60
50
40
30
20
10
0
Characteristic of the transponder when rotated about the polarization axis or orthogonally
to the polarization axis
Transponder/tags
7.7 SIMATIC RF680T
269