The following table shows the most important features of the stationary RF600 readers at a
glance:
Features
Air interface / standards
supported
ETSI variant
FCC variant
LEDs
Interfaces
Number of external
antennas via RTNC
Ethernet
RS232
RS422
Digital inputs
Digital outputs (short-
circuit proof)
Power supply
Max. radiated power
EU, EFTA, Turkey
in ERP
Max. radiated power
USA/China
in EIRP
Max. transmit power
EU, EFTA, Turkey / China
Max. transmit power
USA
Max. transmission rate of the
communication interface
Max. data rate
reader-to-tag
Max. data rate
tag-to-reader
SIMATIC RF600
System Manual, 10/2009, J31069-D0171-U001-A8-7618
SIMATIC RF660R
EPCglobal Class 1, Gen 1,
EPCglobal Class 1, Gen 2,
ISO 18000-6B
Available
Available
3
2 through 4
1x RJ45 connection
according to IEEE 802.3
and ISO 8802-3
1x connector (5-pin M12).
Bit rate: 115200 bps
-
3 (8-pin M12)
log. "0": 0...7 V
log. "1": 15 to 24 V
3 (8-pin M12)
24 V; 0.5 A each
24 V DC (4-pin M12) 20 to
30 V (2.2 A)
external
-
-
0.1 to 2 W
0.24 to 2.4 W
921 kbps
(max. TCP/IP data rate)
80 kbps
160 kbps
SIMATIC RF630R
EPCglobal Class 1, Gen 2
Available
Available
1
1 through 2
-
-
1 x plug (8-pin M12)
-
-
Via ASM
-
-
0.5 W
0.5 W
115.2 kbps
40 kbps
160 kbps
5
SIMATIC RF620R
EPCglobal Class 1, Gen 2
Available
Available
1
-
Integrated antenna
-
-
1 x plug (8-pin M12)
-
-
Via ASM
0.795 W ERP
0.5 W EIRP
-
-
115.2 kbps
40 kbps
160 kbps
79