Status Displays - Siemens SIMATIC RF600 System Manual

Sensors
Hide thumbs Also See for SIMATIC RF600:
Table of Contents

Advertisement

5.1.1.3

Status displays

Status displays
Note
If "Tag Detect" is not lit even though a tag is located within the field, common reasons
include:
• Tag protocol has been set incorrectly (can be set with Configuration Software)
• Tag is defective
• Reader or antenna has a defect
• Tag is not in the field of radiation of the transmit antenna
SIMATIC RF600
System Manual, 10/2009, J31069-D0171-U001-A8-7618
LEDs
Color
Description
Power on
Green
Power supply ON
Tag
Yellow
LED lit, as soon as at least one tag with a correct tag ID is
Detect
within the field.
System
Red
Reader is not active, a more or less major fault has occurred
Error
In addition, this LED also indicates the fault status through
the number of flashing pulses. Reboot (operating voltage Off
→ On is necessary).
The LED flashes once for the 'INACTIVE' status, rebooting is
not necessary in this case.
Readers
5.1 RF660R reader
83