Connecting; Technical Specifications - Siemens SIMATIC Ident System Manual

Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

Accessories
8.3 Wide-range power supply unit for SIMATIC RF systems
8.3.5

Connecting

● There are three different (country-specific) mains cables for the EU, UK and US.
The appropriate mains cable must be connected to the primary input of the power supply.
Note
It is only permissible to insert or remove the mains cable when the power supply is de-
energized.
● The wide-range power supply unit has total insulation (Safety Class 2), IP65
● It can be mounted using four fixing holes.
8.3.6

Technical specifications

General technical specifications
Insulation stability (prim./sec.) U
Insulation resistance R
Leakage current I
Safety class (SELV)
Mains buffering t
Ambient temperature
Surface temperature
Storage temperature
Self-heating on full-load
Interference immunity
ESD
HF fields
Burst
Surge
HF injection
Mains quality test
Cooling
Dimensions L x W x H
Weight
Housing / casting
Power supply class
Degree of protection
MTBF in years
252
ins p/s
ins
U
leak
in
Designed for installation in devices of Safety Class 2
U
h
in
Module top, center
EN 61000-4-2,
4-3 to 4-6, 4-11
according to CSA
IP65
= 230 V
, f = 50 Hz
AC
= 230 V
AC
System Manual, 09/2013, J31069-D0227-U001-A8-7618
3.3 kV
AC
>1 GΩ
< 200 µA
≥ 50 ms
-25 ℃ ... +55 ℃
max. 96 ℃
-40 ℃ ... +85 ℃
max. 45 K
Air discharge: 15 kV
10 V/m
symmetrical: 2
symmetrical: 1
10 V
rms
Free convection
175 mm x 85 mm x 35 mm
720 g
UL 94-V0
Level 3
255