4.2.2

Installing modules on the mounting rail

Accessories
Any accessories you need for installation are in the pack with the modules.
Section 3.6 contains a list of accessories and spare parts, together with the rele-
vant order numbers.
Table 4-3
Module
C230-2
Signal module
(SM)
Sequence in which modules are affixed to the mounting rail
1. Power supply module
2. C230-2
3. Signal module(s)
Installation sequence
The individual steps for the installation of the modules are described below:
1. A bus connector is included with each signal module, but not with the C230-2.
When inserting the bus connectors, always begin with the C230-2.
Take the bus connector from the next module and plug it onto the C230-2's bus
connector (the bus connector is on the back, see Fig. 3-1).
Do not plug a bus link into the "last" module in the line.
2. Fit the modules by hooking them into position, push them against the left-hand
module and lower them down into position.
3. Tighten the module fixing screws, applying a torque of 0.8 to 1.1 Nm.
E Siemens AG, 2003 All rights reserved
SIMOTION C230-2, 04.2003 Edition
Accessories for modules
Accessories supplied
1
slot number plate
2 keys
Labeling plate
1 bus connector
1 labeling plate
Explanation
For the assignment of slot numbers
The key is used to operate the mode selector
for the C230-2.
For labeling of integrated inputs and outputs
of the C230-2
To provide the electrical connections between
the modules
To label the inputs and outputs on the module
Installation
4-67