Siemens SIMATIC S7-1500R Equipment Manual

Siemens SIMATIC S7-1500R Equipment Manual

Hide thumbs Also See for SIMATIC S7-1500R:

Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC S7-1500R

  • Page 2 Preface S7-1500R/H Documentation Guide SIMATIC Product overview Connecting S7-1500R/H CPU 1513R-1 PN Interrupts, diagnostics, (6ES7513-1RL00-0AB0) error messages and system events Equipment Manual Technical specifications Dimension drawing 05/2021 A5E42009333-AC...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Preface

    Preface Purpose of the documentation This manual supplements the system manual of the S7-1500R/H redundant system and the function manuals. This manual contains a description of the module-specific information. The system-related functions are described in the system manual. All system-spanning functions are described in the function manuals.
  • Page 5 Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
  • Page 6 Preface Industry Mall The Industry Mall is the catalog and order system of Siemens AG for automation and drive solutions on the basis of Totally Integrated Automation (TIA) and Totally Integrated Power (TIP). You can find catalogs for all automation and drive products on the Internet (https://mall.industry.siemens.com).
  • Page 7: Table Of Contents

    Table of contents Preface ..............................3 S7-1500R/H Documentation Guide ......................7 Product overview ........................... 9 New functions in firmware version V2.9 ................9 Configuration and operating principle ................13 Hardware properties ......................15 Firmware functions ......................18 Operator controls and display elements ................20 2.5.1 Front view of the CPU with closed front panel ..............
  • Page 8: S7-1500R/H Documentation Guide

    S7-1500R/H system, e.g. diagnostics, communication. You can download the documentation free of charge from the Internet (https://support.industry.siemens.com/cs/ww/en/view/109742691). Changes and supplements to the manuals are documented in a Product Information. You can download the product information free of charge from the Internet (https://support.industry.siemens.com/cs/ww/en/view/109742691).
  • Page 9 You must register once to use the full functionality of "mySupport". You can find "mySupport" on the Internet (https://support.industry.siemens.com/My/ww/en/). Application examples The application examples support you with various tools and examples for solving your automation tasks.
  • Page 10: Product Overview

    As of FW version V2.9, you can influence the switch- PROFINET function manual of switched S1 devices over time between disconnection and return of (http://support.automation.siemens.co switched S1 devices after a failure/STOP of the prima- m/WW/view/en/49948856) ry CPU. This function offers the following advantages: •...
  • Page 11 OB 72 (CPU redundancy As of FW version V2.9, the operating system calls S7-1500R/H System Manual error) OB 72 on further events: (https://support.industry.siemens.com/c s/ww/en/view/109754833) • The R/H-system has entered RUN-Redundant sys- tem state and the synchronization of the two R/H- CPUs is possible redundantly.
  • Page 12 You can download a modified user program into the S7-1500R/H System Manual program in RUN- R/H CPUs in the RUN-Redundant system state. (https://support.industry.siemens.com/c Redundant system state s/ww/en/view/109754833) Advantage: The redundant system will remain con- sistently in the RUN-Redundant system state during the change to the user program.
  • Page 13 Product overview 2.1 New functions in firmware version V2.9 Additional information You can find an overview of all new functions, improvements and revisions in the respective firmware versions on the Internet (https://support.industry.siemens.com/cs/ww/en/view/109478459). CPU 1513R-1 PN (6ES7513-1RL00-0AB0) Equipment Manual, 05/2021, A5E42009333-AC...
  • Page 14: Configuration And Operating Principle

    Product overview 2.2 Configuration and operating principle Configuration and operating principle Structure The S7-1500R redundant system consists of the following components: • Two CPUs of the type CPU 1513R-1 PN • Two SIMATIC memory cards • PROFINET cable (redundancy connections, PROFINET ring) •...
  • Page 15 You mount the CPUs on a standardized 35 mm rail using the standard rail adapter. You will find information on mounting the standard rail adapter in the S7-1500R/H redundant system (https://support.industry.siemens.com/cs/ww/en/view/109754833) System Manual. Principle of operation One of the two CPUs in the redundant system takes on the role of CPU for process control (primary CPU).
  • Page 16: Hardware Properties

    Product overview 2.3 Hardware properties Hardware properties Article number 6ES7513-1RL00-0AB0 View of the module The figure below shows the CPU 1513R-1 PN. Figure 2-2 CPU 1513R-1 PN Note Protective film Note that there is a removable protective foil on the display when the CPUs are delivered. CPU 1513R-1 PN (6ES7513-1RL00-0AB0) Equipment Manual, 05/2021, A5E42009333-AC...
  • Page 17 All CPUs of the redundant system S7 1500R/H have a dis- • Redundant System S7-1500R/H play with plain text information. The display provides you (https://support.industry.siemens with diagnostic messages as well as information about the .com/cs/ww/en/view/109754833) article number, the firmware version and the serial number System Manual of the CPU.
  • Page 18 H-Sync Forwarding when the "ApplicationClass" attribute contains the "HighAvailability" token. You will find more information on H-Sync Forwarding in the system manual S7-1500R/H redundant system (https://support.industry.siemens.com/cs/ww/en/view/109754833). Accessories You can find information on the topic of "Accessories/spare parts" in the system manual for Redundant System S7-1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833).
  • Page 19: Firmware Functions

    CPU redundancy There are two duplicate CPUs that synchronize their Redundant System S7-1500R/H data via redundancy connections within a PROFINET (https://support.industry.siemens.co ring. If one of the CPUs fails, the other CPU retains con- m/cs/ww/en/view/109754833) Sys- trol of the process. tem Manual...
  • Page 20 Integrated technology Integrated closed-loop Function manual PID Control • PID Compact (continuous PID controller) control functionality (https://support.industry.siemens.co • PID 3Step (step controller for integrating actuators) m/cs/ww/en/view/108210036) • PID Temp (temperature controller for heating and cooling with two separate actuators)
  • Page 21: Operator Controls And Display Elements

    Product overview 2.5 Operator controls and display elements Operator controls and display elements 2.5.1 Front view of the CPU with closed front panel The figure below shows the front view of the CPU 1513R-1 PN. ① LEDs for the current operating state and diagnostic status of the CPU ②...
  • Page 22 (local lock) and assign a password for the display. You can find additional information on the display, the configurable protection levels and the local lock in the system manual for Redundant System S7-1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833). Reference You can find detailed information on the individual display options, a training course and a simulation of the available menu commands in the SIMATIC S7-1500 Display Simulator (https://support.industry.siemens.com/cs/ww/en/view/109761758).
  • Page 23: Front View Of The Cpu Without Front Panel

    Product overview 2.5 Operator controls and display elements 2.5.2 Front view of the CPU without front panel The figure below shows the operator controls and connection elements of the CPU 1513R-1 PN. ① LEDs for the current operating state and diagnostic status of the CPUs ②...
  • Page 24: Rear View Of The Cpu

    Product overview 2.5 Operator controls and display elements 2.5.3 Rear view of the CPU The figure below shows the connection elements on the rear of the CPU 1513R-1 PN. ① Shield contact surface ② Plug-in connection for power supply ③ Plug-in connection for backplane bus ④...
  • Page 25: Mode Selector

    You can find a brief overview of the various operating states and system states in the section Status and error display of the CPU (Page 28). You can find a detailed description of the operating states and system states in the system manual for S7-1500R/H Redundant System (https://support.industry.siemens.com/cs/ww/en/view/109754833). CPU 1513R-1 PN (6ES7513-1RL00-0AB0) Equipment Manual, 05/2021, A5E42009333-AC...
  • Page 26: Connecting

    1L+ and 2L+ as well as 1M and 2M are bridged internally. Maximum 10 A permitted You can find information on the various supply options in the system manual for Redundant System S7-1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833). CPU 1513R-1 PN (6ES7513-1RL00-0AB0) Equipment Manual, 05/2021, A5E42009333-AC...
  • Page 27 You can find additional information on the topic of "Connecting the CPU" and on the topic "Accessories/spare parts" in the system manual for Redundant System S7-1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833). Assignment of the MAC addresses CPU 1513R-1 PN has a PROFINET interface with two ports for each CPU. The PROFINET interface itself has a MAC address, and each of the two PROFINET ports has its own MAC address.
  • Page 28 Connecting 3.1 Terminal assignment Block diagram The following figure shows the block diagram of the CPU 1513R-1 PN. ① SIMATIC memory card (X50) PN X1 P1 R PROFINET interface X1 port 1 ② Display PN X1 P2 R PROFINET interface X1 port 2 ③...
  • Page 29: Interrupts, Diagnostics, Error Messages And System Events

    You can find more detailed information on "Interrupts" in the STEP 7 online help. You can find additional information on the topic of "Diagnostics" and "System events" in the Diagnostics (https://support.industry.siemens.com/cs/ww/en/view/59192926) function manual and in the system manual Redundant System S7-1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833).
  • Page 30 Interrupts, diagnostics, error messages and system events 4.1 Status and error display of the CPU LED displays depending on operating states and system states CPU 1513R-1 PN has the following LEDs for displaying the current operating state and diagnostics status. •...
  • Page 31 Interrupts, diagnostics, error messages and system events 4.1 Status and error display of the CPU Meaning of the RUN/STOP, ERROR and MAINT LEDs CPU 1513R-1 PN has three LEDs for displaying the current operating state and diagnostics status. Note LED patterns of the redundant system S7 1500R Note that it is not always possible to: •...
  • Page 32 Interrupts, diagnostics, error messages and system events 4.1 Status and error display of the CPU The following table shows the meaning of the various color combinations for the RUN/STOP, ERROR and MAINT LEDs. Table 4- 1 Meaning of the LEDs RUN/STOP LED ERROR LED MAINT LED...
  • Page 33 Interrupts, diagnostics, error messages and system events 4.1 Status and error display of the CPU Note MAINT LED of the two CPUs The MAINT LEDs of both CPUs only go out when the following conditions are fulfilled: • The CPUs are in the RUN-Redundant system state. •...
  • Page 34: Technical Specifications

    Technical specifications The following table shows the technical specifications as of 05/2021. You can find a data sheet including daily updated technical specifications on the Internet (https://support.industry.siemens.com/cs/ww/en/pv/6ES7513-1RL00-0AB0/td?dl=en). Article number 6ES7513-1RL00-0AB0 General information Product type designation CPU 1513R-1 PN HW functional status...
  • Page 35 Technical specifications Article number 6ES7513-1RL00-0AB0 Load memory 32 Gbyte • Plug-in (SIMATIC Memory Card), max. Backup • maintenance-free CPU processing times for bit operations, typ. 80 ns for word operations, typ. 96 ns for fixed point arithmetic, typ. 128 ns for floating point arithmetic, typ.
  • Page 36 Technical specifications Article number 6ES7513-1RL00-0AB0 Counters, timers and their retentivity S7 counter 2 048 • Number Retentivity adjustable – IEC counter Any (only limited by the main memory) • Number Retentivity adjustable – S7 times 2 048 • Number Retentivity adjustable –...
  • Page 37 Technical specifications Article number 6ES7513-1RL00-0AB0 Number of IO Controllers • integrated Time of day Clock Hardware clock • Type 6 wk; At 40 °C ambient temperature, typically • Backup time 10 s; Typ.: 2 s • Deviation per day, max. Operating hours counter •...
  • Page 38 Technical specifications Article number 6ES7513-1RL00-0AB0 Interface types RJ 45 (Ethernet) • 100 Mbps • Autonegotiation • Autocrossing • Industrial Ethernet status LED Protocols Number of connections • Number of connections, max. • Number of connections reserved for ES/HMI/web Redundancy mode Media redundancy Yes;...
  • Page 39 Technical specifications Article number 6ES7513-1RL00-0AB0 • LLDP Web server • HTTP • HTTPS OPC UA • OPC UA Client • OPC UA Server Further protocols Yes; MODBUS TCP • MODBUS Isochronous mode Equidistance S7 message functions Number of login stations for message func- tions, max.
  • Page 40 Technical specifications Article number 6ES7513-1RL00-0AB0 Diagnostic buffer • present 1 000 • Number of entries, max. of which powerfail-proof – Traces • Number of configurable Traces 512 kbyte • Memory size per trace, max. Interrupts/diagnostics/status information Diagnostics indication LED • RUN/STOP LED •...
  • Page 41 430 g General technical specifications You can find information on the general technical specifications, such as standards and approvals, electromagnetic compatibility, protection class, etc. in the system manual for Redundant System S7-1500R/H (https://support.industry.siemens.com/cs/ww/en/view/109754833). CPU 1513R-1 PN (6ES7513-1RL00-0AB0) Equipment Manual, 05/2021, A5E42009333-AC...
  • Page 42: A Dimension Drawing

    Dimension drawing Dimension drawing This section contains the dimensional drawing of the module on the mounting rail, as well as a dimensional drawing with the front panel open. Keep to the dimensions when installing in cabinets, control rooms, etc. Dimension drawings of the CPU 1513R-1 PN Figure A-1 Dimension drawing of the CPU 1513R-1 PN, front and side view CPU 1513R-1 PN (6ES7513-1RL00-0AB0)
  • Page 43 Dimension drawing A.1 Dimension drawing Figure A-2 Dimension drawing of the CPU 1513R-1 PN, side view with front panel open CPU 1513R-1 PN (6ES7513-1RL00-0AB0) Equipment Manual, 05/2021, A5E42009333-AC...

This manual is also suitable for:

Simatic s7-1500hCpu 1513r-1 pn6es7513-1rl00-0ab0