Proceed as follows:
1. Wire the free cable end of the connecting cable to the terminals on the drive
unit. (The terminal markings on the cable ends indicate the corresponding ter-
minals for SIMODRIVE devices).
2. Open the front cover of the C230-2 and insert the Sub-D socket (50-pin) into
the X2 connector.
3. Lock the connector using the finger screws. Close the front cover.
Connecting cable
The connecting cable is a pre-assembled cable for four axes with an analog inter-
face, terminal designation for SIMODRIVE drives.
The connecting cable is available in a choice of lengths.
See Catalog NC Z or Catalog NC 60 or Catalog ST 70.
Connection diagram
SIMOTION C230-2
CTREN1.1
CTREN1.2
SETP1
REFPOT1
CTREN2.1
CTREN2.2
SETP2
REFPOT2
CTREN3.1
CTREN3.2
SETP3
REFPOT3
CTREN4.1
CTREN4.2
SETP4
REFPOT4
Shield on housing
¬ Wires twisted and shielded in pairs
Fig. 6-7
E Siemens AG, 2003 All rights reserved
SIMOTION C230-2, 04.2003 Edition
14
47
1
34
15
48
35
2
16
49
3
36
17
50
37
4
Shield
Connection diagram of C230-2 to SIMODRIVE 611-A
SIMODRIVE 611-A
¬
9
65
¬
56
14
¬
9
65
¬
56
14
¬
9
65
¬
56
14
¬
9
65
¬
56
14
Connector sleeves
with designations
Wiring
24 V
Input enable
+
Axis 2
Axis 3
Axis 4