Note
If you want to connect incremental encoders without zero signals, then you must
connect the corresponding pins in the connector with the encoder power supply:
Pin 10 with pin 7 or 9 (MEXT)
Pin 11 with pin 4 or 6 (P5EXT)
Absolute encoders (SSI)
Transmission procedure: Serial synchronous interface (SSI) with 5 V differential
Output signal:
Input signal:
Format:
Resolution:
Max. baud rate:
Power consumption:
Encoder supply 5 V
The 5 V supply voltage for the encoders is generated inside the module and is
therefore present at the Sub-D socket. This means you can supply the encoders
via the connecting cable without the need for additional wiring. The voltage
supplied is protected electronically against short circuits and thermal overload, and
it is monitored. The encoder supply is not isolated from the load power supply to
the module.
Encoder supply 24 V
For encoders with an operating voltage of 24 V, the 24 VDC power is supplied to
the Sub-D sockets. This means you can supply the encoders via the connecting
cable without the need for additional wiring. The voltage supplied is protected elec-
tronically against short circuits and thermal overload, and it is monitored. The
encoder supply is not isolated from the load power supply to the module.
E Siemens AG, 2003 All rights reserved
SIMOTION C230-2, 04.2003 Edition
signal transmission (such as the Standard RS422)
Data as non-inverted and inverted signal
Cycle clock shift as non-inverted and inverted signal
Single/Multiturn
Max. 25 bits
1.5 Mbits/s
Max. 300 mA