Battery Troubleshooting - SolarEdge StorEdge SE5000-xxS0 series Installation Manual

For single battery or high capacity
Table of Contents

Advertisement

Battery Troubleshooting

Battery Troubleshooting
The State line in the battery status screen should display one of the following: Charging, Discharging, Idle, 
Off, Init.:
B S N :
X X X X X X X X X
S O E :
8 9 %
T o t a l :
S t a t e :
If Error 186 Battery Comm. Error appears, the battery communication is disconnected. Check the 
l
following:
 
The RS485 control connection to the battery
o
 
The communication DIP switches settings on the battery
o
 
The ID DIP switches setting on the battery
o
If the state Idle is displayed instead of Charging/Discharging, check the following:
l
 
The system configuration
o
 
The DC connection
o
 
The LEDs in the StorEdge Connection Unit - refer to StorEdge Connection Unit LEDs on page 87
o
If Battery Internal Fault is displayed, refer to the battery documentation supplied with it.The 
l
following is an example fault screen.
B a t t e r y
F a u l t
< x x x x >
< x x x x >
Fault # - according to battery
ID - The Modbus ID of the battery
<xxx> - text
84
SolarEdge StorEdge -Single Battery/High Capacity Installation MAN-01-00283-1.1
I D : 2 4
W W W W
P W R :
2 W
< x > W h
C h a r g i n g
I n t e r n a l
< # > ( I D
:
2 4 )