Appendix A: Errors And Troubleshooting; Troubleshooting Communication - SolarEdge SE3K-RWB Installation Manual

Table of Contents

Advertisement

78
  Appendix A: Errors and Troubleshooting

Appendix A: Errors and Troubleshooting

This appendix describes general system problems, and how to
troubleshoot them. For further assistance, contact SolarEdge Support.
For information on the error and warning messages that appear on the
LCD panel when an error occurs, refer to
http://www.solaredge.com/sites/default/files/se-inverter-installation-
guide-error-
codes.pdf
https://www.solaredge.com/sites/default/files/troubleshooting_for_se_
inverter_insallation_guide_addendum_na.pdf.

Troubleshooting Communication

Troubleshooting Ethernet Communication
When using Ethernet communication, use the Server Communication Status window
to identify the location of the error:
S e r v e r : L A N   < S _ O K >
S t a t u s :             < O K >
        x x x x x x x x
< E R R O R M E S S A G E >
xxxxxxxx is a string of 1s and 0s showing an eight-bit communication connection
status. 1 indicates OK and 0 indicates an error.
Bit
Location
1st
LAN Disconnected
2nd
DHCP Failed, or Invalid DHCP Config
3rd
Gateway Ping Failed
4th
G Server Ping Failed
Error Message
Cause and Troubleshooting
Physical connection fault. Check the cable pin-
out assignment and cable connection. Refer to
Creating an Ethernet (LAN) Connection on
page 69
IP settings issue. Check the router and inverter
configuration. Consult your network IT.
Ping to router failed. Check the physical
connection to the switch/router. Check that the
link LED at the router /switch is lit (indicating phy-
link). If OK - contact your network IT, otherwise
replace the cable or change it from cross to
straight connection.
Ping to google.com failed. Connect a laptop and
Three Phase System MAN-01-00507-4.2

Advertisement

Table of Contents
loading

This manual is also suitable for:

Se4k-rwbSe5k-rwb02-70000402-70000502-700006