Creating an Ethernet (LAN) Connection

This communication option enables using an Ethernet connection to connect the inverter to the 
monitoring portal through a LAN.
Ethernet cable specifications:
Cable type – CAT5/CAT6
l
Maximum distance between the inverter and the router – 100 m/ 330 ft. 
l
NOTE
If using a cable longer than 10 m / 33 ft in areas where there is a risk of 
induced voltage surges by lightning, it is recommend to use external surge 
protection devices. For details refer to: 
http://www.solaredge.com/files/pdfs/lightning_surge_protection.pdf.   I f 
grounded metal conduit are used for routing the communication wires, 
there is no need for a lightning protection device. 