Battery Grounding

Battery Grounding
You can connect battery grounding cable either to local ground or to the inverter grounding terminal on 
the AC side. If connecting to the inverter, follow the procedure herein.
To connect grounding to the inverter:
 1. Remove the inverter cover as described in Removing the Inverter Cover on page 34.
 2. Insert the grounding cable using one of the following methods (see Figure 19):
Option 1 - Via the StorEdge Connection Unit glands through the conduit connecting the unit to 
l
the inverter
Option 2 - Directly to the inverter AC terminal via one of the communication glands.
l
 3. Connect the cable to the connection labeled
30
SolarEdge StorEdge -Single Battery/High Capacity Installation MAN-01-00283-1.1
Figure 19: Routing grounding cable from the battery
on the terminal block.