System Warnings
System Warnings
Warnings are displayed in the initial status screen with the format: <Warning X>. For example:
V a c [ V ]
V d c [ V ]
1 . 0
0 . 5
P _ O K :
X X X / Y Y Y
W a r n i n g
8
The warning is a status screen. To view the warning description, press the LCD button.
The following is a list of system warnings:
Warning #
CPU v3.18 and
CPU v3.19 and
below
above
8x66 - 8x69
1-4, 6-7
8x6A - 8x6F
5
8
2x111
SolarEdge-StorEdge -Single Battery/High Capacity Installation MAN-01-00283-1.1
P a c [ W ]
0 . 0
< S _ O K >
O N
LCD text
Fan # Failure
Turn Switch Off to Configure
Connection Unit Low 9V Battery
Comments and troubleshooting
Clean or replace the fan
Appears when trying to access the Setup menus during
production
Replace the 9V battery in the StorEdge Connection Unit.
Refer to 9V Battery Replacement on the next page.
97