Maintenance
Select Maintenance to set the following options:
D a t e
a n d
R e s e t
C o u n t e r s
F a c t o r y
S W
U p g r a d e
D i a g n o s t i c s
G r i d
P r o t e c t i o n
Date and Time: Set the internal real-time clock. If connected to the SolarEdge monitoring portal, the
l
date and time are set automatically and only time zone should be set.
Reset Counters: Resets the accumulated energy counters that are sent to the SolarEdge monitoring
l
portal
Factory Reset: Performs a general reset to the d efault device settings.
l
SW Upgrade SD-Card: Perform a software upgrade using an SD card.
l
Diagnostics: Displays the Isolation Status and optimizers status screens. Refer to
l
www.solaredge.com/files/pdfs/application_note_isolation_fault_
troubleshooting.pdf .
Standby Mode: Enables/disables Standby Mode - for remote commissioning.
l
Grid Protection: Available in specific countries. Enables viewing and setting grid
l
protection values. Refer to http://www.solaredge.com/files/pdfs/viewing_grid_
protection_values.pdf.
Information
Select Information to display the following options:
V e r s i o n s
E r r o r
L o g
W a r n i n g
H a r d w a r e
Versions: Displays inverter firmware versions:
l
ID: The inverter ID.
o
DSP 1/2: The DSP digital control board firmware version
o
CPU: The communication board firmware version
o
NOTE
Please have these numbers ready when you contact SolarEdge Support.
Error Log: Displays the last five errors.
l
Warning Log: Displays the last five warnings.
l
Hardware IDs: Displays the following HW serial numbers (if exist, and connected to the inverter):
l
ID: t he inverter's ID
o
RGM1: Modbus meter (with lower Modbus ID)
o
RGM2: A second external Modbus meter (with the higher Modbus ID)
o
ZB: Z igbee MAC address
o
Cell: MEID (CDMA) or IMEI (GSM)
o
WiFi: Wi-Fi MAC address
o
SolarEdge-StorEdge -Single Battery/High Capacity Installation MAN-01-00283-1.1
T i m e
R e s e t
S D - C a r d
l o g
I D s
Chapter 7: User Interface
51