Wi-Fi Status; Gsm Status - SolarEdge StorEdge SE5000-xxS0 series Installation Manual

For single battery or high capacity
Table of Contents

Advertisement

P A N : X X X X X
C H : X X / X X X X
M I D : X X X X
RSSI: The receive signal strength indication of the closest ZigBee in the system. L = low, M = medium, H 
l
= high and 
(-) = no signal.
PAN ID: The ZigBee transceiver PAN ID
l
Ch.: The ZigBee transceiver channel
l
ID: The ZigBee transceiver ID
l
MID: The Master ID of the coordinator (master) ZigBee module. This field is shown only in devices with 
l
router (slave) ZigBee modules, and after a successful ZigBee association. If a ZigBee module is not 
connected, a No ZigBee message is displayed instead of the MID field.

Wi-Fi Status

This screen describes the Wi-Fi configuration:
I P :
1 9 2 . 1 6 8 . 2 . 1 1 9
G W :
1 9 2 . 1 6 8 . 2 . 1
S S I D :
x x x x x x x x
R S S I :
< L / M / H / - >
IP: The DHCP provided address
l
GW: The gateway IP address
l
SSID: Service Set Identifier - the name of a wireless local area network (WLAN). All wireless devices on a 
l
WLAN must employ the same SSID in order to communicate with each other.
RSSI: The receive signal strength indication of the closest Wi-Fi in the SolarEdge system. L = low, M = 
l
medium, H = high 
and - = no signal.
GSM Status
If a GSM modem is connected, this screen replaces the Server status screen:
S e r v e r : C e l l
S t a t u s :
M N O :
< x x x x x x x >
< E r r o r
Server: The method of communication to the SolarEdge monitoring portal. Should display Cell.
l
Status: Displays OK if the inverter established a successful physical connection to the modem.
l
S_OK: The last communication to the SolarEdge monitoring portal was successful (appears if the 
l
inverter is connected to the portal). If S_OK is not displayed, refer to Status Screens - Operational Mode 
on page 52.
MNO: The mobile network operator name
l
Sig: The signal strength, received from the modem. A value between 0-5, (0 = no signal, 5 = excellent 
l
signal).
Error message per communication connection status failure.
l
SolarEdge-StorEdge -Single Battery/High Capacity Installation MAN-01-00283-1.1
R S S I : < L >
X X
< S _ O K >
< O K >
S i g : 5
m e s s a g e >
Chapter 7: User Interface