1. Turn OFF the inverter ON/OFF switch, and wait until the LCD indicates that the DC voltage is safe
(<50V), or wait five minutes before continuing to the next step.
WARNING!
If you cannot see the inverter panel, or if a malfunction is indicated on the LCD panel, wait five
minutes for the input capacitors of the inverter to discharge.
2. Turn OFF the StorEdge Connection Unit and the AC switch of the distribution panel.
3. Open and remove the StorEdge Connection Unit cover.
4. Open and remove the transparent internal cover.
5. Remove the battery from the upper board of the StorEdge Connection Unit and replace with a new
standard 9V battery.
6. Close the StorEdge Connection Unit covers.
SolarEdge-StorEdge -Single Battery/High Capacity Installation MAN-01-00283-1.1
Appendix C: Replacing and Adding System Components
Figure 46: The battery holder
99