Internal AC Breaker and Bypass Switch

The following components are part of the StorEdge Connection Unit and may be accessed for 
troubleshooting or maintenance.
Backed-up Loads AC Breaker: Main AC breaker for the backed-up loads. Ensure this breaker is UP 
l
before starting up the system.
AC Bypass Switch: This switch bypasses the inverter functionality in case of inverter malfunction. 
l
Maintaining   p ower to the backed-up loads is enabled by connecting the loads directly to the grid. 
There are three switch positions. The following table describes the functionality and use of each 
position:
Switch
Use Case
position
1 (left)
Normal operation
(Default)
2 (right)
AC bypass
0
Not in use

Mounting the Inverter

NOTE
Make sure the mounting surface or structure can support the weight of the inverter and bracket, and
make sure that it spans the width of the bracket.
CAUTION!
HEAVY OBJECT. To avoid muscle strain or back injury, use proper lifting techniques, and if required - a
lifting aid when removing or replacing.
 1. Determine the inverter mounting location, on a wall, stud framing or pole. To allow proper heat
dissipation, maintain the following minimum clearance areas between the inverter and other objects:
SolarEdge-StorEdge -Single Battery/High Capacity Installation MAN-01-00283-1.1
Figure 7: StorEdge Connection Unit
Normal operation.
The backed-up loads panel is connected through the software
controlled switches to the AC grid (during normal operation), or to the
inverter (via auto-transformer, for backup power).
This mode disables the backup functionality.
The backed-up loads panel is connected directly to the AC grid through
the bypass switch. Use in case of inverter malfunction.
Chapter 3: Installing the Inverter
Functionality
19