Audio scope screen
This audio scope enables you to display the received
signal's frequency component on the FFT scope, and
its waveform components on the Oscilloscope. The
FFT scope also has an waterfall.
Display the AUDIO SCOPE screen.
» AUDIO
MENU
AUDIO SCOPE screen
Key
Selects the attenuator for the FFT
Touch
scope.
• 0 (OFF), 10, 20, or 30 dB
ATT
Touch for
Turns OFF the attenuator. (0 dB)
1 second
Sets the Hold function to ON or OFF.
HOLD
• "
" is displayed and freezes the current
HOLD
audio spectrum.
Selects the Oscilloscope level.
LEVEL
• 0, –10, –20, or –30 dB
Selects the Oscilloscope sweep time.
TIME
• 1, 3, 10, 30, 100, or 300 ms/Div
Selects the Expanded or Normal
Touch
screen.
EXPD/
SET
Touch for
Enters the AUDIO SCOPE SET
1 second
screen.
• AUDIO SCOPE screen
MAIN/SUB band icon*
Waterfall zone
FFT Scope zone
*Touching the MAIN/SUB band icon selects the displayed band.
Action
Oscilloscope
D AUDIO SCOPE SET screen
This screen is used to set the FFT scope waveform
type, color, Waterfall display and oscilloscope
waveform color.
1. Display the AUDIO SCOPE screen.
» AUDIO
MENU
2. Touch [SET].
3. Touch to select the item to set.
(Example: "FFT Scope Waveform Type")
4. Touch the option to set.
L See below for details on the setting items and their
options.
5. To close the AUDIO SCOPE SET screen, push
.
EXIT
TIP: You can set each item to its default by touching
the item for 1 second, and then touching "Default" on
the QUICK MENU.
FFT Scope Waveform Type
Select the type of waveform for the FFT scope.
• Line: Only the waveform outline is drawn.
• Fill: The full waveform is drawn in color.
FFT Scope Waveform Color
Set the waveform color for the FFT scope.
L Touch and select the R (Red), G (Green) or B (Blue)
scale, and then rotate
to 255.
L The color is displayed in the box above the RGB scale.
FFT Scope Waterfall Display
Turn the Waterfall display ON or OFF.
• OFF: Turns OFF the Waterfall display.
• ON:
Turns ON the Waterfall display.
Oscilloscope Waveform Color
Set the waveform color for the Oscilloscope.
L Touch and select the R (Red), G (Green) or B (Blue)
scale, and then rotate
to 255.
L The color is displayed in the box above the RGB scale.
5-3
SCOPE OPERATION
(Default: Fill)
(Default: (R) 51 (G) 153 (B) 255)
to adjust the ratio from 0
MULTI
(Default: ON)
(Default: (R) 0 (G) 255 (B) 0)
to adjust the ratio from 0
MULTI
5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
Need help?
Do you have a question about the IC-9700 and is the answer not in the manual?
Questions and answers
Hi I cannot get my ic7900 to work on independe freq and green light sub is on plus I got main rev and sub in my screen .and cannot get my transceiver work with DUB function.on 2 meter please can you help ?
To resolve the issue where the Icom IC-9700 is not working on an independent frequency with the green Sub light on and the Dualwatch (DUB) function not functioning on 2 meters:
1. Confirm Dualwatch is Enabled: Hold down the OFF button for 1 second to turn the Dualwatch function ON. This activates independent monitoring of both Main and Sub bands.
2. Select the Proper Band: Touch the grayed frequency readout to select the active band. Ensure the Main and Sub bands are set to different frequencies and not both on 2 meters, as the same frequency cannot be set on both bands.
3. Check Band Settings: Ensure that the Sub band is not set to the same frequency or band as the Main. The IC-9700 supports independent operation on different bands, but not the same frequency on both Main and Sub.
4. Verify TX is on Main Band: Transmission is only possible on the Main band (except in Split Frequency mode), so ensure the Main band is the one you intend to transmit on.
5. Check for Mode Compatibility: Some functions only apply to the selected band and mode. Confirm that the correct mode (FM, SSB, etc.) is selected for the band in use.
Following these steps should allow independent frequency operation with Dualwatch enabled.