Panasonic FP2 ET-LAN Technical Manual page 280

Table of Contents

Advertisement

- Auto connection status check area (Bank: 10H)
Address
Name
040H
Auto connection function
status
041H
Normal connections 1 to 8
Open processing setting
procedure
042H
System connection 1 status
(SC1)
043H
System connection 2 status
(SC2)
044H
System connection 3 status
(SC3)
045H
Reserved
to
04FH
15-18
Explanation
0: Auto connection function is invalid.
1: Auto connection function is valid.
0: Setup tool setting is valid. (Ladder program setting is invalid.)
1: Ladder setting is valid. (Setup tool setting is invalid.)
0: Open processing wait status
1: Open processing has been completed.
2: Connection is ongoing.
FF: Open processing has been ended in error.
0: Open processing wait status
1: Open processing has been completed.
2: Connection is ongoing.
FF: Open processing has been ended in an error.
0: Open processing wait status
1: Open processing has been completed.
2: Connection is on going.
FF: Open processing has been ended in an error.
Reserved (Used in the system.)

Hide quick links: