Address
Name
208H
No
communication
connection time
type
209H
No
communication
connection
detection timer
value
20AH
TCP ULP
(packet existence
duration)
20BH
TCP zero-window
timer value
20CH
TCP re-
transmission
timer value
20DH
TCP closed timer
value
20EH
IP assembling
timer value
20FH
Reserved
(Used by the
system.)
15-6
Default
Set value and explanation
0000H
Set the base time for the no communication connection
detection timer value.
0000H : x 2 minutes
Other than 0000H : x 6 seconds
0000H
Setting time = [Setting value (1 - FFFFH)] x [Base time]
- Set the time to detect a no-communication state after
connection establishment.
- The setting value of the above 208H is used as the base time.
- When the setting value is larger than 0064H,
in case of x 2 minutes : 200 minutes
in case of x 6 seconds : 10 minutes
000FH
Setting time = [Set value (1 to FFFFH)] x 2 seconds
[30 seconds]
- With TCP, this specifies the time that a packet exists when data
transmission, etc. is carried out.
0005H
Setting time = [Set value (1 to FFFFH)] x 2 seconds
[10 seconds]
- With TCP, this specifies the time until the receive window size
check packet is re-sent when the receive window size of the
other node becomes 0.
0005H
Setting time = [Set value (1 to FFFFH)] x 2 seconds
[10 seconds]
- With TCP, this specifies the time until data is re-sent if ACK is
not sent by the other node, when data transmission, etc. is
carried out.
0001H
Setting time = [Set value (1 to FFFFH)] x 2 seconds
[2 seconds]
- This specifies the time waited until open processing is carried
out when the same port is being re-opened, when TCP close
processing is done by the source node.
000FH
Setting time = [Set value (1 to FFFFH)] x 2 seconds
[30 seconds]
- This specifies the time waited for the next portion of data when
data split by the IP is being received.
-
When any value is written, it should be 0000H.