Eaton Power Xpert C445 User Manual page 226

Global motor management relay
Hide thumbs Also See for Power Xpert C445:
Table of Contents

Advertisement

Table 106. Motor Protection Object—Class 0xA2 (162), continued
Instance Attributes
Sr. No.
Attribute ID
Access
5
5 (0x5)
Get/Set
6
6 (0x6)
Get/Set
7
7 (0x7)
Get/Set
8
8 (0x8)
Get/Set
9
9 (0x9)
Get/Set
10
10 (0xA)
Get/Set
11
11 (0xB)
Get/Set
12
12 (0xC)
Get/Set
13
13 (0xD)
Get/Set
14
14 (0xE)
Get/Set
15
15 (0xF)
Get/Set
16
16 (0x10)
Get/Set
17
17 (0x11)
Get/Set
18
18 (0x12)
Get/Set
19
19 (0x13)
Get/Set
20
20 (0x14)
Get/Set
21
21 (0x15)
Get
22
22 (0x16)
Get
Data Type
Attribute Name
BYTE
Auto reset enable capability for each trip
bit
UINT
Reset time delay. The amount of time to
wait until we do an auto reset.
BOOL
Perform reset on power up.
UINT
Motor State time delay after which the
RUN state is declared if not reached via
current thresholds.
BOOL
Start inhibited protection enable when
motor is up to speed.
UINT
Phase Rotation
UINT
Protection Instantaneous Overcurrent Trip
Level
UINT
Protection Instantaneous Overcurrent
Debounce
UINT
Protection Instantaneous Overcurrent
Alarm Level
UINT
Protection Instantaneous Overcurrent
Start Delay
USINT
Protection UnderCurrent Trip Level
UINT
Protection UnderCurrent Trip Debounce
USINT
Protection UnderCurrent Alarm Level
USINT
Protection I Unbalance Trip Percent Level Protection I Unbalance Trip Percent Level
UINT
Protection I Unbalance Trip Debounce
Time
USINT
Protection I Unbalance Alarm Percent
Level
USINT
I Phase Loss Trip Level in percent
UINT
I Phase Loss Debounce
Power Xpert C445 Global Motor Management Relay MN042003EN—October 2016 www.eaton.com
Appendix C—Optional Communication Cards
Attribute Description
Per tripping type auto reset enable bits.
Bit location - condition
0 - under voltage
1 - over voltage
2 - high resistance GF
3 - residual GF
4 - current phase loss
5 - current unbalance
6 - instantaneous over current
7 - jam
8 - PF deviation
9 - voltage phase loss
10 - voltage unbalance
11 - freq deviation fast
12 - freq deviation slow
13 - under current
14 - high power
15 - low power
16 - overload
17 - stall
18 - phase rotation
19 - exceeds starts limit
20 - PTC
21 - initialization fault
22 - NV memory fault
23 - comm loss
24 - comm msg error
Time delay before auto-reset
Protection allowed after delay since start
Motor State time delay after which the RUN state is
declared if not reached via current thresholds.
If enabled, only allows protection when motor is up to
speed
Phase Rotation
Protection Instantaneous Overcurrent Trip Level
Protection Instantaneous Overcurrent Debounce
Protection Instantaneous Overcurrent Alarm Level
Protection Instantaneous Overcurrent Start Delay
Protection UnderCurrent Trip Level
Protection UnderCurrent Trip Debounce
Protection UnderCurrent Alarm Level
Protection I Unbalance Trip Debounce Time
Protection I Unbalance Alarm Percent Level
I Phase Loss Trip Level in percent
I Phase Loss Debounce
213