NAiS FP Series User Manual page 92

Applicable plc
Hide thumbs Also See for FP Series:
Table of Contents

Advertisement

FPΣ
Program
When X5 is turned on, Y0 turns on and the conveyor begins moving. When the elapsed
value (DT90044 and DT90045) reaches K5000, Y0 turns off and the conveyor stops.
X5
R903A
DF
R100
R100
DF
R101
F1 DMV
K 0
F167 HC1R K 0
Sets high- speed counter CH0
When elapsed value reaches 5,000
R101
R903A
R100
DF/
R102
Figure 80: FPΣ High- speed counter function - sample program 1 (program)
R102
R100
R101
,DT 90044
,K 5000
,Y 0
Y0 goes off
Y0
T0
R102
TMX 0, K 5
6.3 High - speed Counter Function
Positioning operations running
Positioning operations start
Resets elapsed value of high- speed counter
CH0
Target value match off instruction
Y0 goes off when elapsed value of high- speed
counter CH0 reaches 5,000 pulses
S
Set the inverter operation signal "Y0"
Posotioning done pulse (0.5 s)
0.1 s type timer
Setting K5 and using it as a 0.5 s timer
6 - 17