Specifications
Address Name
DT90170
MEWNET - W0
PLC link status
PLC link status
DT90171
DT90172
DT90173
DT90174
DT90175
DT90176
DT90177
DT90178
DT90179
DT90180
Not used
to
DT90189
DT90190
High- speed counter control
flag monitor for ch0
DT90191
High- speed counter control
flag monitor for ch1
DT90192
High- speed counter control
flag monitor for ch2
DT90193
High- speed counter control
flag monitor for ch3
Not used
DT90194
to
DT90199
DT90200
High- speed
counter elapsed
counter elapsed
DT90201
value
DT90202
High- speed
counter target
value
DT90203
DT90204
High- speed
counter elapsed
counter elapsed
DT90205
value
13 - 38
Description
Duplicated destination for PLC inter- link address
Counts how many times a token is lost.
Counts how many times two or more tokens are
detected.
Counts how many times a signal is lost.
No. of times undefined commands have been
received
No. of times sum check errors have occurred
during reception
No. of times format errors have occurred in re-
ceived data
No. of times transmission errors have occurred
No. of times procedural errors have occurred
No. of times overlapping parent units have occurred
This monitors the data specified in DT90052.
Home near input
High - speed counter instruction
Pulse output
Hardware reset
H d
Count
Software reset
For ch2
The elapsed value (32-bit data) for the high-speed
counter is stored here. The value can be read and
counter is stored here. The value can be read and
written by executing F1 (DMV) instruction.
For ch2
The target value (32-bit data) of the high-speed
counter specified by the high-speed counter
instruction is stored here.
Target values have been preset for the various
Target values have been preset for the various
instructions, to be used when the high-speed
counter related instruction "F166, F167, F171 , F175
or F176" is executed. The value can be read by
executing F1 (DMV) instruction.
For ch3
The elapsed value (32-bit data) for the high-speed
counter is stored here The value can be read and
counter is stored here.The value can be read and
written by executing F1 (DMV)instruction.
(A: Available, N/A: Not available)
Reading
A
N/A
A
4
3
2
1
0
0: Invalid/1: Valid
0: Continue/1: Clear
0: Continue/1: Stop
0: Enable/1: Disable
E
bl /
Di
bl
0: Enable/1: Disable
0: No/1: Yes
N/A
A
A
A
FPΣ
Writing
N/A
N/A
N/A
N/A
A
N/A
A