Specifications
No.
Name
Special instructions
F138
Hours, minutes
and seconds
data to seconds
data
F139
Seconds data to
hours, minutes
and seconds
data
F140
Carry flag set
F141
Carry flag reset CLC
F143
Partial I/O
update
F147
Printout
F148
Self-diagnostic
error set
F149
Message
display
F157
Time addition
F158
Time
substruction
F159
Serial data
communication
BIN arithmetic instruction
F160
Double word
(32-bit) data
square root
High - speed counter and pulse output control instructions
F0
High - speed
counter and
pulse output
control
F1
Change and
read of the
elapsed value
elapsed value
of high - speed
counter
Note
The elapsed value area varies depending on the channel being
used.
13 - 58
Boolean
Operand Description
HMSS
S, D
Converts the hour, minute and second data of (S+1, S)
to seconds data, and the converted data is stored in
(D+1, D).
SHMS
S, D
Converts the seconds data of (S+1, S) to hour, minute
and second data, and the converted data is stored in
(D+1, D).
STC
Turns on the carry flag (R9009).
Turns off the carry flag (R9009).
IORF
D1, D2
Updates the I/O from the number specified by "D1" to
the number specified by "D2".
Only possible for I/O numbers in a range of X0 to XF
and Y0 to YF.
PR
S, D
Converts the ASCII code data in the area starting with
"S" for printing, and outputs it to the word external out-
put relay WY specified by "D".
ERR
n
Stores the self-diagnostic error number "n" in DT90000
(n: K100
turns R9000 on, and turns on the ERROR/ALARM LED.
to K299)
MSG
S
Displays the character constant of "S" in the connected
programming tool.
CADD
S1, S2, D
The time after (S2+1, S2) elapses from the time of
(S1+2, S1+1, S1) is stored in (D+2, D+1, D).
CSUB
S1, S2, D
The time that results from subtracting (S2+1, S2) from
the time (S1+2, S1+1, S1) is stored in (D+2, D+1, D).
MTRN
S, n, D
This is used to send data to or receive data from an
external device through the specified COM., RS232C
or RS485 port.
DSQR
S, D
√(S) → (D)
MV
S,
Performs high- speed counter control according to the
DT90052
control code specified by "S".
DMV
S,
Transfers (S+1, S) to high- speed counter elapsed val-
DT90044
ue area (DT90045, DT90044). (* Note)
DT90044,
Transfers value in high- speed counter elapsed value
D
area (DT90045, DT90044) to (D+1, D). (* Note)
FPΣ
Steps
5
5
1
1
5
5
3
13
9
9
7
7
5
7
7