7.4.2
Tool for Tightening Communication Connector Terminal Block
When tightening the terminals of the communication connector, use a screwdriver
"Phoenix Contact Co., Product No. 1205037, blade size of 0.4 2.5, model No. SZS 0,4
x 2,5" or screwdriver "Part No. AFP0806". The tightening torque should be 0.22 to 0.25
N⋅m or less.
7.4.3
Wiring Method
Procedure:
1. Remove a portion "7 mm/0.276 in." of the wire's insulation.
7 mm
Figure 137: FPΣ Communication connector wiring method 1
2. Insert the wire into the terminal block until it contacts the
back of the block, and then tighten the screw clockwise to
fix the wire in place.
Figure 138: FPΣ Communication connector wiring method 2
7.4.4
Cautions Regarding Wiring
The following items should be observed, taking care not to cut or disconnect the wiring.
- When removing the wire's insulation, be careful not to scratch the core wire.
- Do not twist the wires to connect them.
- Do not solder the wires to connect them. The solder may break due to vibration.
- After wiring, make sure stress is not applied to the wire.
- In the terminal block socket construction, if the wire closes upon counter-clockwise
rotation, the connection is faulty. Disconnect the wire, check the terminal hole, and
then re-connect the wire.
CORRECT
(Clockwise)
Figure 139: Cautions regarding wiring