VeEX MTT-14B User Manual page 64

Shdsl module
Table of Contents

Advertisement

MTT-14B e_Manual D07-00-083P RevA00
Programming a Burst of 10 Errors
1. Select ERROR INJECTION.
2. At TYPE, press CODE (F1) to select the error type.
3. At MODE, press BURST (F1).
4. At COUNT. Press SHIFT and enter 10 using the numeric
keypad. Press SHIFT when finished.
5. Press ENTER and the test set is set inject 10 CODE errors
each time ERR INJ is pressed.
Programming a 10-6 Bit Error Rate
1. Select ERROR INJECTION.
2. At TYPE, press BIT (F2) to select the error type.
3. At MODE, press RATE (F2).
4. At COUNT. Press SHIFT and use the numeric keypad to press
1. The multiplier position shows 1. The cursor moves to the
exponent position. Now press 6. When finished, press SHIFT.
5. Press ENTER and the test set is set to inject Bit errors at 1x10
rate each time ERR INJ is pressed. To turn off the error rate
injection, press ERR INJ once then verify that the on screen
ERR INJ indicator is off.
Page 64 of 101
-6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rxt-2140

Table of Contents