Profile; Profile Configuration Screen - VeEX MTT-14B User Manual

Shdsl module
Table of Contents

Advertisement

MTT-14B e_Manual D07-00-083P RevA00

2.2.4.4 Profile

The PING setup screens feature a
PROFILE (F1) key. This allows
saving and retrieving various
configurations. To save a
configuration, use this procedure:
1. From any PING configuration
screen, select MODE and
press PROFILE (F1) and a
PING Profile list screen is
displayed.
Figure 15 Profile Configuration Screen
2. Use
to select a blank line and press EDIT (F1) to display
the configuration screen shown in Figure 15.
3. With the cursor on the PROFILE NAME line, give the Profile a name
by pressing EDIT (F1). A character entry screen is displayed.
4. Press INPUT (F3) to select the character grid and use
to move the cursor to the desired character. Press
ENTER to select the character and the selected character
appears on the PROFILE NAME line. Repeat until finished.
• If a mistake is made; press STOP (F3), use
incorrect character and then press:
-
DELETE (F2) to delete the character.
-
INSERT (F1) to add a character left of the selected character.
-
OVER (F1) to replace a character with another character.
5. When finished, press STOP (F3) to exit the character grid.
6. Press F4 to save the PROFILE NAME and return to the PING
configuration screen.
7. Select MODE, choose the mode for the PING and configure
the remainder of the screen as in the previous PING configu-
ration sections. When finished, press F4 to save the profile.
Invoking a Profile
1. From MODE, press PROFILE (F1) and in the PING Profile list
screen use
to select a saved profile.
2. Press SELECT (F4) then F3 to start the PING test.
Editing a Saved Profile
1. From MODE, press PROFILE (F1) and in the PING Profile list
screen use
to select a saved profile.
3. Press EDIT (F1) and the Profile Configuration screen is dis-
played as in Figure 15.
4. Make any required changes by using the procedures in the
first part of this section.
5. When finished, press F4 to save the altered Profile.
12:30:55
>LINK UP
4W STU-R<
PROFILE NAME
:
MODE
:LLC-BRG
ENCAPSULATION :LLC
VPI
:8
VCI
:35
IP ADDRESS
:STATIC
LOCAL IP
:003.044.055.066
DESTINATION IP:001.333.452.012
GATEWAY
:005.180.190.200
EDIT
SAVE
to select the
Page 25 of 101

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rxt-2140

Table of Contents