E1 G.821 Screen; E1 Alarm/Signal Screen; E1 M.2100/550 Screen - VeEX MTT-14B User Manual

Shdsl module
Table of Contents

Advertisement

MTT-14B e_Manual D07-00-083P RevA00

E1 G.821 Screen

This screen presents the mea-
surement parameters specified
in ITU G.821. See Section
2.3.3.1 for measurement defini-
tions.

E1 Alarm/Signal Screen

This screen presents alarm and
measurement parameters
relating to the E1 signal. See
Section 2.3.3.1 for measure-
ment definitions.

E1 M.2100/550 Screen

This screen provides pass/fail
measurements in accordance
with ITU M.2100/550. This is
used where a 2.048 Mbit/s
circuit passes through interna-
tional boundaries. It allocates a
certain allowable error rate to
each nation that carries the
circuit.
The following definitions pertain to this screen:
PERIOD: Identifies the date and time interval of each of the
reported pass or fail results.
08:39:57
>LINK UP
ET
: 001:04:13 RT
FRM : PCM-30/C
TxCK: L1-Rx
PATT: 2e15
RATE: 2.048M
E1 G.821
BIT - 0
BER - 0.00E-08
ES
- 0
%ES - 0.00
SES - 0
%SES- 0.00
EFS - 0
%EFS- 100.00
AS
- 3002
%AS - 100.00
UAS - 0
%UAS- 0.00
SLIP- 0
DGRM- 0
%DGRM- 0.000
PAGE-UP PAGE-DN
STOP
Figure 35 E1 G.821 Screen
08:39:57
Meas
>LINK UP
ET
: 001:04:13 RT
FRM : PCM-30/C
TxCK: L1-Rx
PATT: 2e15
RATE: 2.048M
E1 ALARM/SIGNAL
LOSS: 0
AISS: 0
LOFS: 0
FALM: 0
MFAL: 0
PAGE-UP PAGE-DN
STOP
Figure 36 E1 Alarm/Signal Screen
08:39:57
>LINK UP
ET
: 001:04:13 RT
FRM : PCM-30/C
TxCK: L1-Rx
PATT: 2e15
RATE: 2.048M
E1 M2100/550
PERIOD
P/F
09-12 12:16/12:32
P
09-12 12:32/12:47
P
09-12 12:47/13:02
P
09-12 13:02/13:17
P
09-12 13:17/13:32
P
09-12 13:32/13:47
P
PAGE-UP PAGE-DN
STOP
Figure 37 E1 M.2100/550 Screen
Meas
STU-C E1<
: CONTINU
MORE
STU-C E1<
: CONTINU
MORE
Meas
STU-C E1<
: CONTINU
%ES
%SES
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
MORE
Page 58 of 101

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rxt-2140

Table of Contents