Alarm Status; Alarm Status Screen - VeEX MTT-14B User Manual

Shdsl module
Table of Contents

Advertisement

MTT-14B e_Manual D07-00-083P RevA00

2.2.2 Alarm Status

This screen provides
general alarm status
(current and history for
local and remote).
Note CH2 is reported
only in 4-wire mode.
This screen reports the following:
SNR: Triggered when the local current SNR margin value is below
the user threshold setting. This is set in MODEM CONTROL >
SYSTEM SETTINGS, on the SNR MARGIN THRESHOLD line.
LOSW: Loss of Sync defect alarm, a loss of synchronization word
defect is declared when at least 3 consecutive received frames
contain 1 or more errors. An LOSW defect is cleared when at
least 2 consecutive received frames contain no errors.
ATTN: Triggered when the local attenuation value is greater than
the user threshold value. This is set in MODEM CONTROL >
SYSTEM SETTINGS, on the LOOP ATTN THRESHOLD line.
These alarm conditions are displayed as current and history.
These are defined as:
curr YES: The alarm condition is currently detected.
curr NO: The alarm condition is not currently detected.
hist YES: The alarm condition has been detected, but it is no
longer present.
hist NO: The alarm condition has never been detected since the
start of the test or since pressing HISTORY.
The following F-keys are available:
PRINT (F3): Send the alarm screen to the serial port.
STORE (F4): Press to store the status screen.
08:39:57
>LINK UP
4W STU-R<
ALARM STATUS
LOCAL
REMOTE
curr
hist
curr
CH1 -
SNR :
NO
NO
NO
LOSW:
NO
NO
NO
ATTN:
NO
NO
NO
CH2 -
SNR :
NO
NO
NO
LOSW:
NO
NO
NO
ATTN:
NO
NO
NO
PRINT
Figure 6 Alarm Status Screen
hist
NO
NO
NO
NO
NO
NO
STORE
Page 12 of 101