Email Settings

Email settings
The Email application on the UCM6100 can be used to send out alert event Emails, Fax (Fax-To-Email),
Voicemail (Voicemail-To-Email) etc. The configuration parameters can be accessed via Web GUI→System
Settings→Email Settings→Email Settings.
TLS Enable
Type
Domain
Server
Username
Password
Enable Email-to-Fax

Table 22: Email Settings

Enable or disable TLS during transferring/submitting your Email to
another SMTP server. The default setting is "Yes".
Select Email type.
MTA: Mail Transfer Agent. The Email will be sent from the
configured domain. When MTA is selected, there is no need to set
up SMTP server for it or no user login is required. However, the
Emails sent from MTA might be considered as spam by the target
SMTP server.
Client: Submit Emails to the SMTP server. A SMTP server is
required and users need login with correct credentials.
Specify the domain name to be used in the Email when using type
"MTA".
Specify the SMTP server when using type "Client".
Username is required when using type "Client". Normally it's the Email
address.
Password to login for the above Username (Email address) is required
when using type "Client".
Enable or Disable Email-to-Fax feature.
If enabled, the UCM will monitor the configured email inbox (using
provided [Username] and [Password]) for emails with the subject
"SendFaxMail To XXX". Example : SendFaxMail To 7200
The UCM will extract the attachments of detected emails and send it to
the XXX extension by fax.
The attachment must be in PDF/TIF/TIFF format.
Note: This field will appear when using Type "Client".
UCM6100 Series User Manual
Version 1.0.18.13
P a g e
|
97