Connection Examples (Electrical) - Festo MS6-SV Operating Instructions Manual

Soft start/quick exhaust valve
Table of Contents

Advertisement

Available languages

Available languages

MS6(N)−SV
Inputs and outputs
Terminal in
I/O
multi−pin plug
socket NECA
1
EN1
2
EN2
3
13
4
14
5
A5
6
S34
7
8
+L1
9
M
Fig. 7
6

Connection examples (electrical)

Note
The wires for the enable signals should be laid separately from the power
supply. In addition, the wires should be protected against damage using
suitable measures.
Note
For easier commissioning, we recommend planning a reset button (normally
closed) in the power supply circuit. This simplifies resetting in case of fault.
Festo MS6(N)−SV 0904a English
Assignment
Enable signal 1
(static or dynamic)
Enable signal 2
(static or dynamic)
Signal contacts, NO
Contact for Automatic
start" operation mode
Contact for Automatic
start" or Monitored
start" operation mode
Operating voltage
GND
as per EN 61131−2
type 2, max. 6 mA
as per EN 61131−2
type 2, max. 6 mA
potential−free
Max. 120 mA
Max 120 mA
as per EN 61131−2
type 2, max. 6 mA
+24 V DC ±10 %
è
examples in chapter 6,
Connection examples"
è
examples in chapter 6,
Connection examples"
è
examples in chapter 6,
p
p
Connection examples"
C
ti
l "
è
examples in chapter 6,
Connection examples"
è
examples in chapter 6,
Connection examples"
45