Operation

Safety note
In its process−reliable (i.e. pressurised) state, the MS6(N)−SV's mechanical
system is not tested. If the process−related switching frequency (reliable
exhausting) is less than once a month, the machine's operator has to carry out a
forced switch off.
Note
The pause period after venting is 1 s. Only after this time is a new swtich−on
accepted and performed.
9

Care and maintenance

Switch off the following sources of energy before cleaning the exterior of the
S
device:
Operating voltage
Compressed air supply
If necessary, clean the exterior of the MS6(N)−SV.
S
Soap suds (max. +50 °C), petroleum ether and all non−abrasive cleaning agents
may be used.
10

Dismantling

1. Switch off the following sources of energy before dismantling:
Operating voltage
Compressed air supply
2. Disconnect the relevant connections of the MS6(N)−SV.