Festo MS6-SV Operating Instructions Manual page 55

Soft start/quick exhaust valve
Table of Contents

Advertisement

Available languages

Available languages

MS6(N)−SV
Input and output switching characteristics in normal operation (when the Automatic start"
operation mode is set) for NECA−S1G9−P9−MP3 multi−pin plug
Operat. pressure p1
Output pressure p2
+L1: Operating voltage
EN1: Enable signal 1
EN2: Enable signal 2
13/14: Signal contacts
Power LED (green)
Error LED (red)
Fig. 15
Venting and output of an error message occurs when:
EN1 and EN2 = 0 V (LOW)
S
EN1 and EN2 = 24 V (HIGH)
S
The diagrams on the next page show the precise switching characteristics of the Enable signals
EN1 and EN2 with a time offset. The maximum reaction time can be derived from the delay
between the two signals.
Festo MS6(N)−SV 0904a English
55

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Ms6n-sv

Table of Contents