MS6(N)−SV

Signal contacts 13/14

The signal contacts 13/14 are potential−free normally open contacts of a
semiconductor relay. Through terminals 3 and 4 of the NECA multi−pin plug socket,
the message can be picked up in the feedback circuit of a safety control system.
Alternatively, the information can be reported back to the controller via an
attached pressure sensor (only MS6(N)−SV−...−AD...).
Note
Assignment of these contacts is not required to achieve the safety category.
Fig. 12
The diagrams for the switching characteristics can be found in the chapter 7
Commissioning" (with multi−pin plug socket NECA−S1G9−P9−MP1 è Fig. 13 and
Fig. 14 / with multi−pin plug socket NECA−S1G9−P9−MP3 è Fig. 15 and Fig. 16).