Diagnostics And Error Handling; Led Display; Fault Code - Festo MS6-SV Operating Instructions Manual

Soft start/quick exhaust valve
Table of Contents

Advertisement

Available languages

Available languages

MS6(N)−SV
13

Diagnostics and error handling

LED display

Operating statuses and faults are indicated by flashing LEDs.
Power LED (green)
off
lights up for approx.
6 s after switching on
flashes at 1 second
intervals
permanently
illuminated
4 x briefly
Fig. 18

Fault code

The fault code is indicated by 4 brief flashes of the Power LED (green). Then the
Error LED (red) displays the fault code (number of flash pulses = fault code).
The flash pulses for both LEDs repeat continuously. The LEDs only stop flashing
when the operating voltage is switched off in order to eliminate the fault.
Overview of the fault codes:
Fault code
6, 8
All other fault codes
Fig. 19
Festo MS6(N)−SV 0904a English
Error LED (red)
off
lights up for approx.
6 s after switching on
off
off
flashes at 1 second
intervals
Fault
Pneumatic fault or electrical installation fault
Internal fault
Diagnosis
Operating voltage not applied
MS6(N)−SV runs through all tests
when started up
MS6(N)−SV is in the exhaust state
MS6(N)−SV is in the pressurise state
Fault code
59

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Ms6n-sv

Table of Contents