Operation mode selectors

The door functions are set with different operate mode selectors.
The operation mode selector is available with 5 buttons (plus RESET).
The key on the PSK-6U mode selector must always be removed on emergency escape doors after
changing settings.

Functions

CM-No.
12-553
OPEN, AUTO PARTIAL, AUTO, ONE WAY and OFF functions can be obtained.
R
701002
1008972
*
1007926
1008140
1008773
1008132
*
724462
*
1008102
Art.no.
Material
-
Proj. method
Scale
Drawn
Date
1:1
ASE
2012-04-03
Description
MODE SELECTOR
40x80 FLUSH 5 SYMB
Note! If monitored emergency unit is a demand, a test of the emergency unit is performed when
the operate mode selector is set from OFF or OPEN to any other operation mode.
1009216-EI-4.0
Done
Date
JOB
2012-11-06
Symbol
Text
OPEN
AUTO
PARTIAL
AUTO
ONE
WAY
OFF
Remark
Remark
Status
Approved
Rev.
Size
Sheet
2.0
A3
1 (1)
Drawing No.
1008174
RESET
RESET
R
PSK-6U
Function
The door is permanently open. The door can be moved by hand
e.g. for window cleaning. All activation units except for the emer-
gency push button (if fitted) are disconnected.
Two-way traffic, AUTO PARTIAL is obtained. The door can be
opened partially with the inner and outer activation units and with
a key switch (if fitted). With an emergency push-button the door
opens fully.
Two-way traffic, normal operation of the door. The door can be
opened with the inner and outer activation units and with a key
switch/emergency push-button (if fitted).
Passage from inside only. The door is normally locked if an elec-
tromechanical locking device has been fitted. The door can only
be opened with the inner activation unit or with a key
switch/emergency push-button (if fitted).
This function is only used on emergency escape doors after it is
certain that all people have left the building.
The door cannot be opened with inner and outer activation units.
The door is locked if an electromechanical locking device has been
fitted. The door can be opened partially with a key switch (if fitted).
With an emergency pushbutton (if fitted) the door opens fully.
The door can also be opened partially from the operation mode
selector if the arrow down button is held for 2 seconds. No access
code is necessary for this and the key impulse is indicated by briefly
showing a blue light to the left of the open symbol or text and
then a flashing blue light to the left of the closed symbol or text
for another 15 seconds.
By briefly pushing the globe of the logotype with a narrow object,
the door operator will make a RESET function with a system test.
The door will return to the closed position (if not in operation
mode selection OPEN or if an error is present) and is then ready
for normal operation.
Turn the key clockwise to the position "R" (six o'clock) and insert
a narrow object in the small hole on the operation mode selector
and push briefly. Then turn the key counter-clockwise back to the
requested setting and the door operator will make a RESET function
with a system test. The door will return to the closed position (if
not in operation mode selection OPEN or if an error is present)
and is then ready for normal operation.
Note! The key cannot be removed in the "R" position.