Configuring The Temperature Alarm Thresholds - HP 10500 Series Configuration Manual

Hide thumbs Also See for 10500 Series:
Table of Contents

Advertisement

Figure 52 Memory alarm notification and alarm-removed notification
Free memory space
Normal
Severe
Critical
To set memory alarm thresholds:
Step
1.
Enter system view.
Set the memory
2.
usage threshold.
3.
Set the free-memory
thresholds.

Configuring the temperature alarm thresholds

The device monitors its temperature based on the following thresholds:
Low-temperature threshold.
High-temperature warning threshold.
High-temperature alarming threshold.
Minor
alarm
Minor
Severe alarm
Critical alarm
Command
system-view
In standalone mode:
memory-threshold [ slot slot-number
[ cpu cpu-number ] ] usage
memory-threshold
In IRF mode:
memory-threshold [ chassis
chassis-number slot slot-number [ cpu
cpu-number ] ] usage
memory-threshold
In standalone mode:
memory-threshold [ slot slot-number
[ cpu cpu-number ] ] minor
minor-value severe severe-value
critical critical-value normal
normal-value
In IRF mode:
memory-threshold [ chassis
chassis-number slot slot-number [ cpu
cpu-number ] ] minor minor-value
severe severe-value critical
critical-value normal normal-value
230
Minor alarm-removed
Severe alarm-removed
Critical alarm-removed
Remarks
N/A
The default memory usage threshold
is 100%.
The defaults are as follows:
Minor alarm threshold—96 MB.
Severe alarm threshold—64
MB.
Critical alarm threshold—48
MB.
Normal state threshold—128
MB.