Setting The Port Status Detection Timer; Configuring Temperature Thresholds For A Card - HP 830 Series Configuration Manual

Poe+ unified wired-wlan switch
Hide thumbs Also See for 830 Series:
Table of Contents

Advertisement

Setting the port status detection timer

Some protocols might shut down ports under specific circumstances. For example, MSTP shuts down a
BPDU guard–enabled port when the port receives a BPDU. In this case, you can set the port status
detection timer. If the port is still down when the detection timer expires, the protocol module
automatically cancels the shutdown action and restores the port to its original physical status.
To set the port status detection timer:
Step
1.
Enter system view.
2.
Set the port status detection
timer.

Configuring temperature thresholds for a card

You can set the temperature thresholds to monitor the temperature of a card.
When the temperature drops below the lower threshold or reaches the warning threshold, the
device logs the event and outputs a log message and a trap.
When the temperature reaches the alarming threshold, the device logs the event and outputs a log
message and a trap repeatedly in the terminal display, and alerts users through the LED on the
device panel.
Support for this feature depends on your device model. For more information, see About the HP 830
Series PoE+ Unified Wired-WLAN Switch and HP 10500/7500 20G Unified Wired-WLAN Module
Configuration Guides.
To configure temperature thresholds:
Step
1.
Enter system view.
2.
Configure temperature
thresholds for a card.
Command
system-view
shutdown-interval time
Command
system-view
temperature-limit slot slot-number
{ inflow | hotspot } sensor-number
lowerlimit warninglimit
[ alarmlimit ]
114
Remarks
N/A
By default, the port status detection
timer is 30 seconds.
Remarks
N/A
By default, the temperature thresholds
for a card vary with devices. For more
information, see About the HP 830
Series PoE+ Unified Wired-WLAN
Switch and HP 10500/7500 20G
Unified Wired-WLAN Module
Command References.
The warning and alarming thresholds
must be higher than the lower
temperature threshold.
The alarming threshold must be higher
than the warning threshold.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

105007500

Table of Contents