Configuring the temperature alarm thresholds

You can set a lower temperature threshold, warning temperature threshold, and alarming temperature
threshold to monitor the temperature of the device through its temperature sensors.
When the temperature drops below the lower temperature threshold or reaches the warning temperature
threshold, the device logs the event and sends out a log message and a trap.
When the temperature reaches the alarming temperature threshold, the device logs the event and notifies
users by repeatedly sending log messages and traps and by setting the LEDs on the device panel.
To configure the temperature alarm thresholds:
Step
1.
Enter system view.
2.
Configure the temperature
alarm thresholds.

Disabling all USB interfaces

This feature is supported only on the default MDC.
You can use USB interfaces to upload or download files. By default, all USB interfaces are enabled. You
can disable USB interfaces as needed.
To disable all USB interfaces:
Command
In standalone mode:
memory-threshold [ slot slot-number ]
minor minor-value severe severe-value
critical critical-value normal normal-value
In IRF mode:
memory-threshold [ chassis
chassis-number slot slot-number ] minor
minor-value severe severe-value critical
critical-value normal normal-value
Command
system-view
In standalone mode:
temperature-limit slot
slot-number { hotspot | inflow |
outflow } sensor-number
lowerlimit warninglimit
[ alarmlimit ]
In IRF mode:
temperature-limit chassis
chassis-number slot slot-number
{ hotspot | inflow | outflow }
sensor-number lowerlimit
warninglimit [ alarmlimit ]
189
Remarks
The defaults are as follows:
Level-1 threshold—96 MB.
Level-2 threshold—64 MB.
Level-3 threshold—48 MB.
Normal level threshold—128 MB.
Remarks
N/A
The alarming threshold must be
higher than the warning threshold,
and the warning threshold must be
higher than the lower temperature
threshold.